Detection oils: Crude oil, gasoline, diesel fuel, kerosene, heavy fuel oil, lubricating oil, organic solvents, animal and vegetable fats and oils
| Specifications | |
| Sensor - Apolarm™CSR-3005 | |
| Minimum detectable oil layer thickness | 3 to 5 mm |
| Detection oils | Crude oil, gasoline, diesel fuel, kerosene, heavy fuel oil, lubricating oil, organic solvents, animal and vegetable fats and oils |
| Housing structure | Watertight, IEC Class IP67 equivalent |
| Explosion-proof rating | IEC Ex ia IIC intrinsic safety certified |
| Operating temperature | -20 to + 60°C (liquid layers must be free from freezing) |
| Dimensions | 300 mm diam. X 140 mm H |
| Weight | Approx. 2.6 kg (excluding sensor cable) H |
| Signal cable(included) | PVC sheathing, two 0.2 mm 2 wires, 12 m length Highly flex-, heat-, and oil-resistant |
| Max. cable length | Extension up to 2 km maximum (limit under IIC T4 rating) |
| Signal Converter - AS-40 | |
| Relay contacts | Form C configuration for both oil detection signal and system malfunction signal; terminals rated 250 V AC, 4 A |
| Operating temperature | 10 to + 50°C |
| Power source | 100-110 V AC or 200-220 V AC, 50 or 60 Hz |
| Dimensions (W x H x D) |
80 x 120 x 76 mm |
| Weight | Approx. 0.8 kg |
| Sensor - MicroApolarm™CSR-1505 | |
| Minimum detectable oil layer thickness | 3 to 5 mm |
| Detection oils | Crude oil, gasoline, diesel fuel, kerosene, heavy fuel oil, lubricating oil, organic solvents, animal and vegetable fats and oils |
| Housing structure | Watertight, IEC Class IP67 equivalent |
| Housing material | High impact PVC |
| Electrode material | SUS 316 |
| Operating temperature | -20 to + 60°C (liquid layers must be free from freezing) |
| Dimensions | Approx. 150 mm diam. X 60 mm H |
| Weight | Approx. 170 g |
| Attached cable | 0.2 mm sq. , 2-wire, 12 m |
| Max. cable length | 2 km (limit with IIC T4 rating) |
| Signal Converter - AS-20 | |
| System alarm | Initiated by power loss at signal converter, cable disconnect, or cable short-circuit |
| Delay timer | Adjustable, approx. 1-10 sec |
| Power source | AC100/110V, 200/220V; 50/60 Hz |
| Power consumption | Approx. 2VA |
| Relay contacts | Form C configuration for both oil detection signal and system malfunction signal |
| Terminal rating | AC250V, 4A; DC30V, 4A |
| Operating temperature | -10 to + 50°C |
| Operating humidity | 95% RH |
| Power source | 100-110 V AC or 200-220 V AC, 50 or 60 Hz |
| Dimensions (W x H x D) |
80 x 120 x 76 mm |
| Weight | Approx. 0.8 kg |
SAME PRODUCTS